Application
Rural water supply and garden irrigation
HVAC and circulation & pressure boosting for cold and hot water
Long-distance water transfer or supporting equipment
Transfer clean water or other liquids similar in physical and chemical properties
Pump
Cast iron pump body
PPO impeller
AISI 304 shaft
Max. liquid temperature: +60℃
Max. suction: +9m
Moter
Motor with copper winding
Build-in thermal protector for single phase motor
Insulation class: F
Protection class: IPX4
Max. ambient temperature: +40℃
Quality Control
The shallow well pump should be installed in a dean, dry and ventilated location which provides adequate room for servicing and protection from freezing temperatures. It should be bolted to a good foundation, preferably concrete and provided adequate drainage.
OPERATION WARNING
Do not run the transfer pump without water as the seals and impeller may be permanently damaged. Pouring clean water until pump chamber and the inlet pipe are completely filled.
Technical Date
Model |
Power |
DN |
Q(m³/h) |
0 |
0.5 |
1 |
1.5 |
2 |
2.5 |
3 |
3.5 |
4 |
4.5 |
5 |
5.5 |
6 |
|
kW |
HP |
Q(L/min) |
0 |
8.3 |
16.7 |
25 |
33.3 |
41.7 |
50 |
58.3 |
66.7 |
75 |
83.3 |
91.7 |
100 |
||
DSC(m)70/037 |
0.37 |
0.5 |
1.2"×1" |
H(m) |
16.6 |
15.5 |
15 |
14 |
13.5 |
12.5 |
11.5 |
10.5 |
10 |
/ |
/ |
/ |
/ |
DSC(m)70/055 |
0.55 |
0.75 |
1.2"×1" |
23.6 |
22.6 |
21.6 |
20.7 |
19.7 |
18.6 |
17.7 |
16.4 |
15.1 |
13.4 |
/ |
/ |
/ |
|
DSC(m)70/075 |
0.75 |
1.1 |
1.2"×1" |
25.2 |
24 |
23.2 |
22.9 |
22 |
20.8 |
20 |
19.2 |
18 |
16.8 |
14.9 |
/ |
/ |
|
DSC(m)70/110 |
1.1 |
1.5 |
1.2"×1" |
27.6 |
26.5 |
26 |
25.7 |
25.3 |
24.5 |
24 |
23.3 |
22.8 |
22 |
21.4 |
20.4 |
19.8 |
|
DSC(m)70/150 |
1.5 |
2 |
1.2"×1" |
33.1 |
32.5 |
31.6 |
31 |
30.4 |
29.8 |
28.5 |
28 |
27.8 |
27.2 |
25 |
25.31 |
24 |
Performance Curve
Model Analysis